Secondary power supply redundant skat-v 24dc-18 rack

Price
7 210 266,7 UZS
Brand
БАСТИОН
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

SKAT-V.24DC-18 Rack (SKAT UPS-24/18-RACK)

is designed to provide uninterruptible power supply to fire and intrusion alarm systems, video surveillance and other consumers with a rated supply voltage of 24 V DC and a maximum total load current, including the battery charging current, of 18 A.

The secondary power supply

SKAT-V.24DC-18 Rack (SKAT UPS-24/18-RACK)

is housed in a 2U enclosure and is designed for installation in 19" racks or cabinets.

FEATURES OF SKAT-V.24DC-18 RACK (SKAT UPS-24/18-RACK)

supplies the load with stabilized DC voltage while mains voltage is present ("MAIN" mode) according to item 2 of the table, with total consumption current including battery charging current of no more than 18 A;

charges the battery from the 220 V, 50 Hz mains according to item 1 of the table, with battery charging voltage according to item 3 of the table ("MAIN" mode) and charging current according to item 6 of the table;

limits the battery charging current (item 6 of the table) and allows selection of one of four limit current values;

temperature compensation of the battery charging voltage while mains is present, according to item 4 of the table (when the battery temperature sensor is used, included in the delivery set);

automatic switchover to load supply from the external battery at DC voltage according to item 2 of the table, with consumption current of no more than 18 A, when mains voltage drops below the value specified in item 1 of the table or when mains power is disconnected ("RESERVE" mode);

protection of the source and the load against incorrect battery connection (reverse polarity) of the terminals by means of a fuse;

short-circuit protection of the battery terminals;

battery presence control;

protection of the battery against deep discharge in "RESERVE" mode by disconnecting the load from the battery when the battery terminal voltage drops to the level specified in item 9 of the table;

light indication of the operating mode by LED indicators "MAINS", "BATTERY", "OUTPUT", "FAULT";

protection of the mains supply against short circuit in the source by means of a fuse;

"cold start" function, restoring the operability of the source when a serviceable and charged battery is connected in the absence of mains voltage, by pressing the "cold start" button;

output of informational diagnostic messages (connection of external indication circuits) and/or control of external automation devices by the normally open contacts of three signal relays.