Temperature controller F&F rt-820 m EA07.001.007

Price
702 583,7 UZS
Brand
F&F
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

Distinctive features: Supply voltage 24-264 V DC / 30-264 V AC, range from -30 to +140 °C, hysteresis 0.5-30 °C, contact 1NO, 16 A. Time delays.

Purpose

Designed to control and maintain a set temperature regime based on signals from a remote temperature sensor in premises, vegetable storage facilities, water heating systems and similar applications, by switching a heating or cooling unit on and off.

Scope of application

Used in systems that require constant temperature control and maintaining the thermal regime at the facility within a set range.

Features

- adjustable temperature range from -30 to +140 °C;

- remote temperature sensor RT823 (sensing element type KTY81/210), supplied as standard;

- operating mode selection: “Heating” or “Cooling”;

- adjustable temperature hysteresis 0.5…30 °C;

- additional contact group for connecting an alarm;

- alarm indication on the display when the temperature exceeds the set value by 5 °C (display blinks at 0.5 Hz);

- ability to limit the maximum operating duration and the minimum downtime of the heating/cooling unit;

- ability to set a delay before the temperature controller switches on after power is applied;

- recording with storage in memory of the minimum and maximum measured temperature;

- password protection of the temperature controller settings;

- sensor reading correction within ±9.9 °C;

- monitoring of the remote temperature sensor’s serviceability;

- maximum load current 16 A.

Operating principle

The temperature controller operates the heating (cooling) electrical equipment in one of two modes: “Heating” or “Cooling”.

Heating mode

When the temperature in the temperature control zone drops below the value set on the thermostat, the contacts of the actuating relay close and the heating equipment is switched on. When the set temperature is reached, the controller switches off the heating unit. When the temperature drops by the set hysteresis value, the contacts of the actuating relay close again and the heating equipment is switched on again.

Cooling mode

When the temperature in the temperature control zone rises above the value set on the thermostat, the contacts of the actuating relay close and the cooling equipment (fan, air conditioner) is switched on. When the set temperature is reached, the controller switches off the cooling equipment. When the temperature rises by the set hysteresis value, the contacts of the actuating relay close again and the equipment is switched on again.