SHUM-PLUG silencers are designed to reduce the noise generated by the VIR fan and the air flow in high-pressure ventilation and air conditioning systems. Effective noise reduction across a wide frequency range, including the high-frequency range. Low aerodynamic resistance, thanks to the rounded corners on the frame of the noise-absorbing plates, ensures high energy efficiency.
Silencers are manufactured in rectangular cross-section and consist of a rigid box-type casing made of 3-4 mm steel, with flanges made in one piece with the structural metal. To increase rigidity, the wall corners are welded and stiffening ribs are welded to the side walls. The horizontal walls gain rigidity through the attachment of noise-absorbing plates. Casing rigidity and strength are critical, since the silencer is installed in a high-pressure duct, and also to avoid additional noise from casing vibration and noise transmission into the room.
It consists of a rigid box-type casing made of 3-4 mm steel, with flanges made in one piece with the structural metal. Inside the casing are installed noise-absorbing plates 200 or 300 mm thick, filled with sound-absorbing mineral fibre. The sound-absorbing material is covered with glass fleece and a perforated sheet that protects the material from erosion at air speeds up to 20 m/s. The frame of the noise-absorbing plate has rounded corners, which reduces aerodynamic resistance by 25-30% and contributes to high energy efficiency.
The casing is made of carbon steel with basalt-grey RAL 7012 powder coating (design H) or of stainless steel (design K). The plate frame is made of galvanized steel (design H) or stainless steel (design K).
Installation is possible in any spatial orientation.
A straight section of duct at least 1 m long is recommended in front of the silencer; this is needed to equalise the air speed across the duct cross-section.
When installing the silencer after a duct bend, a straight duct section equal to 1.5 times the height of the silencer plate must be provided. If the plates are installed horizontally, where the duct width equals the plate height, the plate height must be taken into account.
To further reduce noise, several silencers can be installed in series, adding duct sections at least 1 m long between them.
Specifications
- Silencer for high-pressure VIR fans. Execution: N - general industrial execution
- K - corrosion-resistant execution
- V - explosion-proof execution
Similar products
Compressor-condensing units MAKK 320
Compressor-condensing units MAKK 310
VKI compressor and evaporative units
Drycoolers MAVO.D.4
Drycoolers MAVO.D.3
Drycoolers MAVO.D.2
Counter flange FOT-OSA
Flange reverse FON for radial fans
Flange reverse FON for industrial fans
Flange reverse FOV
Flange reverse FOV
Filter FIVK
Company products
Hydromodule AquaVENS 2.0 KNB
Hydromodule AquaVENS 2.0 kN
Water condenser units BVK
Compressor-condenser units with reversible refrigeration circuit MAKK-T 320
Noise suppressor SHUM-PLAST
Noise suppressor SHUM-PLAG-VD
Noise suppressor SHUM-OSA
Noise suppressor SHUM-KONUS
Noise suppressor SHUM-VD
Noise suppressor SHUM-AK-VD
Noise suppressor SHUM-AK for radial fans
Noise suppressor SHUM-AK for axial fans