# VECTOR control unit standard version

> VECTOR control unit standard version — The "Vector" control unit (UR "Vector") is designed for automatic control of the parameters of the heat (cold) carrier…

URL: https://b2bmarket.uz/product/vector-standart?lang=en

[Home](https://b2bmarket.uz/home?lang=en) › [Catalog](https://b2bmarket.uz/catalog?lang=en) › [Construction and real estate](https://b2bmarket.uz/catalog?category_id=stroitelstvo-i-nedvijimost&lang=en) › [Heating, ventilation and air conditioning systems](https://b2bmarket.uz/catalog?category_id=stroitelstvo-i-nedvijimost&subcategory_id=sistemi-otopleniya-ventilyatsii-i-konditsionirovaniya&lang=en) › VECTOR control unit standard version

- **Price:** On request
- **Brand:** WINDCOM
- **Country:** Uzbekistan
- **Supplier:** WINDCOM
- **City:** Tashkent

![VECTOR control unit standard version](https://b2bmarket.uz/api/uploads/vezaimg/23930.webp) ![VECTOR control unit standard version — photo 2](https://b2bmarket.uz/api/uploads/vezaimg/23936.webp) ![VECTOR control unit standard version — photo 3](https://b2bmarket.uz/api/uploads/vezaimg/23939.webp)

The "Vector" control unit (UR "Vector") is designed for automatic control of the parameters of the heat (cold) carrier and for ensuring its circulation when ventilation supply systems (heat exchangers, air heaters, air coolers) or other heat energy consumption systems (air heating – heating units, heat air curtains) are connected to a heat (cold) source.

UR "Vector" is a set of pipework, shut-off, control and protective fittings (if provided in the scheme), pumping equipment (if provided in the scheme), and instrumentation (if provided in the scheme).

The design of UR "Vector" is determined by the following schemes:

1 — smooth regulation;

2 — mixing with smooth regulation;

3 — diverting circuit;

4 — diverting circuit with mixing;

4M — modification of scheme 4 (maximum heat carrier temperature in the supply line increased to +150 &deg;C, provided the temperature of the heat carrier returning from the consumer is not more than +120 &deg;C);

5 — mixing circuit without fittings in the mixing branch;

5M — modification of scheme 5 (fittings added in the mixing branch);

6 — open/closed;

6M — open/closed with pump.

The UR "Vector" line is divided by type of control device:

C — a seat valve with electric actuator and smooth regulation is used as the control device. Connection to heat (cold) supply and consumption systems — flanged.

Sh — a rotary valve with electric actuator and smooth regulation is used as the control device (for VEKTOR-6(M) — open/closed electric actuator). Connection to heat (cold) supply and consumption systems — threaded.

Connection side to the consumer

P — right

L — left

The UR is manufactured according to technical specifications at a modern high-tech plant, ensuring high quality and reliability of the product.

UR "Vector" is certified for compliance with TU BY 810000679.041-2014 and GOST 12.2.003.

The following is used as the heat (cold) carrier for UR "Vector":

mains water according to SP 124.13330.2012 "SNiP 41-02-2003 Heat networks".

high-resource special solution of the "AkvaTerma" and "AkvaTermaEKO" brands (based on ethylene glycol or propylene glycol), provided the pump capacity is recalculated taking into account the characteristics of the heat carrier.

## Specifications

- Heat carrier temperature up to +50…120…150 °C (determined by the scheme)
- Operating pressure up to 1 MPa
- Applicable heat carriers:
- – mains water per SP 124.13330.2012 “SNiP 41-02-2003. Heating networks”,
- – industrial heat carriers based on ethylene and propylene glycol, with a concentration of up to 50% of the main substance
- Ambient temperature from +5° to +40 °C
- Relative humidity must not exceed 50% at a temperature of +40 °C.

## Similar products

- [Hatch HODOZOR-100](https://b2bmarket.uz/product/hodozor-100?lang=en)
- [Smoke hatch DYMOZOR-300](https://b2bmarket.uz/product/dymozor-300?lang=en)
- [Smoke hatch DYMOZOR-200](https://b2bmarket.uz/product/dymozor-200?lang=en)
- [Smoke hatch DYMOZOR-100](https://b2bmarket.uz/product/dymozor-100?lang=en)
- [Aeration hatch AEROSOR-500](https://b2bmarket.uz/product/aerosor500?lang=en)
- [Aeration hatch AEROSOR-400](https://b2bmarket.uz/product/aerosor400?lang=en)
- [Chillers AquaMARK 341](https://b2bmarket.uz/product/aqua-marc-341?lang=en)
- [Chillers AquaMARK 301](https://b2bmarket.uz/product/aqua-marc-301?lang=en)
- [Chillers AquaMAKK 432](https://b2bmarket.uz/product/aqua-macc-432?lang=en)
- [Chillers AquaMAKK 331](https://b2bmarket.uz/product/aqua-macc-331?lang=en)
- [Chillers AquaMAKK 321](https://b2bmarket.uz/product/aqua-macc-321?lang=en)
- [Fan coil VENDO-ST](https://b2bmarket.uz/product/vendo-ct?lang=en)

## Company products

- [Aeration hatch AEROSOR-300](https://b2bmarket.uz/product/aerosor300?lang=en)
- [Aeration hatch AEROZOR-200](https://b2bmarket.uz/product/aerosor200?lang=en)
- [Aeration hatch AEROSOR-100](https://b2bmarket.uz/product/aerosor100?lang=en)
- [Smoke hatch DYMOZOR-600](https://b2bmarket.uz/product/dymozor-600?lang=en)
- [Smoke hatch DYMOZOR-500](https://b2bmarket.uz/product/dymozor-500?lang=en)
- [VECTOR control unit, street version](https://b2bmarket.uz/product/vector-ulichnyy?lang=en)
- [VECTOR control unit special design](https://b2bmarket.uz/product/vector-spetsialnyy?lang=en)
- [Individual heating point BASIS standard version](https://b2bmarket.uz/product/bazis-standart?lang=en)
- [Individual heating point BASIS special design](https://b2bmarket.uz/product/bazis-special?lang=en)
- [Individual heating point BASIS block design](https://b2bmarket.uz/product/bazis-block?lang=en)
- [Chillers AquaMARK 452](https://b2bmarket.uz/product/aqua-marc-452?lang=en)
- [Chillers AquaMARK 402](https://b2bmarket.uz/product/aqua-marc-402?lang=en)

## Supplier

- [WINDCOM](https://b2bmarket.uz/@windcom?lang=en)