# Supply roof fan VKOP

> Supply roof fan VKOP — Execution: General industrial (H). Roof fans for smoke control pressurization systems (SP) are installed on building roofs. They…

URL: https://b2bmarket.uz/product/vkop?lang=en

[Home](https://b2bmarket.uz/home?lang=en) › [Catalog](https://b2bmarket.uz/catalog?lang=en) › [Construction and real estate](https://b2bmarket.uz/catalog?category_id=stroitelstvo-i-nedvijimost&lang=en) › [Heating, ventilation and air conditioning systems](https://b2bmarket.uz/catalog?category_id=stroitelstvo-i-nedvijimost&subcategory_id=sistemi-otopleniya-ventilyatsii-i-konditsionirovaniya&lang=en) › Supply roof fan VKOP

- **Price:** On request
- **Brand:** WINDCOM
- **Country:** Uzbekistan
- **Supplier:** WINDCOM
- **City:** Tashkent

![Supply roof fan VKOP](https://b2bmarket.uz/api/uploads/vezaimg/22465.webp) ![Supply roof fan VKOP — photo 2](https://b2bmarket.uz/api/uploads/vezaimg/22468.webp) ![Supply roof fan VKOP — photo 3](https://b2bmarket.uz/api/uploads/vezaimg/22471.webp)

Execution:

General industrial (H).

Roof fans for smoke control pressurization systems (SP) are installed on building roofs. They provide direct supply of outdoor air from the space above the roof into stairwell and elevator zones, creating overpressure in stairwells, elevator shafts and other zones and preventing smoke from entering these premises. This simplifies the ventilation system and frees up working space on the technical floor.

According to SP 7.13130.2013 &laquo;Heating, ventilation and air conditioning. Fire safety requirements&raquo;, the pressure differential at a closed door between a stairwell with supply ventilation and an auxiliary room/corridor must not exceed the minimum limit of 20 Pa.

The pressurization system is used to minimize the possible dangerous smoke spread in shafts during firefighting and rescue operations and fire brigade work.

The pressure differential system activates automatically by means of spot smoke detectors located on the ceiling of the served area next to the doors leading to the protected area served by the system, which are present

on each floor.

In addition to creating pressurization, there is another very important function &ndash; compensation for smoke exhaust (SE) systems, since removing the gas-air mixture from a sealed room is incorrect. Supplying air into the lower zone creates a protected space for people and reduces the heat load from fire products on building structures. Designing any SE system involves calculating and selecting a compensating supply system. For example, for smoke extraction from corridors, the compensation is pressurization of the adjacent stairwells. An exhaust SE/EDU system without compensating inflow cannot operate.

The roof supply unit VKOP&reg;-2019 is a new unique development of 2019 by the company &laquo;VEZA&raquo;. The basis of VKOP* is an axial fan of updated design with a more efficient impeller. VKOP includes a specially designed mounting base, which is an integral part of the unit and is used for roof installation according to SP 17.13330.2017 &laquo;SNiP II-26-76 ROOFS&raquo;.

The selection of VKOP-2019 models has been expanded: low-pressure variants have been added, and excessive capacities and pressures have been removed.

The VKOP&reg; installation has 4 types of base: &bull;01 &bull;02 &bull;03 &bull;04, which ensure a smooth transition of the airflow from round to square cross-section in the roof, improving system performance.

Base 01 has a minimum height H=600 mm, bases 02, 03 and 04 have a height H=1000 mm.

Bases 03 and 04 have a built-in inertial-type check valve, which is closed when the fan is not running, opens under the action of the airflow, and closes when the fan is switched off due to gravity. This prevents intensive heat escape through the roof shaft and the fan.

The valve built into base 04 is insulated.

## Specifications

- The VKOP unit has 4 base types: 01, 02 without damper
- 03 with damper
- 04 with insulated damper
- Static pressure up to 1000 Pa
- Airflow: 4000 ... 42000 m3/h
- Electric motor: asynchronous
- Motor installed power: 0.55 ... 7.5 kW
- Weight: 74 ... 635 kg.

## Similar products

- [Protection from precipitation for radial fans ZONT](https://b2bmarket.uz/product/zont?lang=en)
- [Inlet manifold VKO for radial fans](https://b2bmarket.uz/product/vko-vd?lang=en)
- [Inlet manifold VKO for axial fans](https://b2bmarket.uz/product/vko-osa?lang=en)
- [Radial fan VRAN](https://b2bmarket.uz/product/vran?lang=en)
- [Radial fan VRAV](https://b2bmarket.uz/product/vrav?lang=en)
- [Prop fan VRAN-PD](https://b2bmarket.uz/product/vran-pd?lang=en)
- [Roof fan UKROS-DU](https://b2bmarket.uz/product/ukros-do?lang=en)
- [Roof smoke exhaust fan UKROV-DUV](https://b2bmarket.uz/product/ventilyator-kryshnyj-dymoudaleniya-ukrov-duv?lang=en)
- [Roof smoke exhaust fan UKROV-DU](https://b2bmarket.uz/product/ukrov-do?lang=en)
- [Roof fan for smoke removal KROS-DUV](https://b2bmarket.uz/product/kros-duv?lang=en)
- [Roof fan for smoke removal KROS-DU](https://b2bmarket.uz/product/cros-do?lang=en)
- [Roof smoke exhaust fan KROV-DUV](https://b2bmarket.uz/product/ventilyator-kryshnyj-dymoudaleniya-krov-duv?lang=en)

## Company products

- [Axial fan OSA-E](https://b2bmarket.uz/product/osa-e?lang=en)
- [Axial fan OSA 301](https://b2bmarket.uz/product/osa301?lang=en)
- [Axial fan OSA 300](https://b2bmarket.uz/product/osa300?lang=en)
- [Roof fan UKROS](https://b2bmarket.uz/product/ukros?lang=en)
- [Roof fan UKROV](https://b2bmarket.uz/product/ukrov?lang=en)
- [Roof supply fan VKOP0](https://b2bmarket.uz/product/vkop0?lang=en)
- [Roof fan KROSH](https://b2bmarket.uz/product/krosh?lang=en)
- [Roof fan KROS](https://b2bmarket.uz/product/kros?lang=en)
- [Roof fan KROM-SH](https://b2bmarket.uz/product/krom-sh?lang=en)
- [Roof fan KROM](https://b2bmarket.uz/product/krom?lang=en)
- [Roof fan KROV](https://b2bmarket.uz/product/krov?lang=en)
- [Roof smoke exhaust fan UKROS-DUV](https://b2bmarket.uz/product/ventilyator-kryshnyj-dymoudaleniya-ukros-duv?lang=en)

## Supplier

- [WINDCOM](https://b2bmarket.uz/@windcom?lang=en)