VP — Wires for industrial blasting operations

Price
On request
Brand
Uzkabel
Country
Uzbekistan
Supplier
Eltexsanoat
City
Tashkent

GOST 6285-74

APPLICATION:

The wires are intended for industrial blasting operations: wires with a conductor diameter of 0.5 mm are used as leads of electric igniters, those with diameters of 0.7 and 0.8 mm for trunk lines.

The wires are designed for short-term operation at 380 V and instantaneous operation at 660 V AC or 1500 V DC. Operation at instantaneous DC voltage up to 3000 V is permitted.

Specifications

  • GRADES AND DESIGN:
  • VP - copper-core wires with polyethylene insulation for blasting operations.
  • Conductor – copper, solid, round, diameters 0.5
  • 0.7 or 0.8 mm.
  • Insulation – polyethylene
  • insulation colours of the two-core wire must differ.
  • Twisting – the insulated cores of the two-core wire are twisted with a lay of not more than 20 twist diameters.
  • TECHNICAL CHARACTERISTICS:
  • Climatic versions O and T, placement categories 1 – 5 per GOST 15150.
  • DC conductor resistance at 20 °C per 1 km: 0.5 mm conductor - not more than 93 Ω
  • 0.8 mm - not more than 36 Ω
  • 0.7 mm - not more than 50 Ω.
  • The wire and insulated cores withstand a spark test with AC voltage of at least 50 Hz: 0.5 mm conductor - 3000 V
  • 0.7 and 0.8 mm conductors - 5000 V.
  • Delivery length: 0.5 mm conductor - not less than 1500 m
  • 0.7 and 0.8 mm conductors - not less than 500 m.
  • Warranty: 1 year from the date of manufacture.