Roof fan UKROS

Price
On request
Brand
WINDCOM
Country
Uzbekistan
Supplier
WINDCOM
City
Tashkent

UKROS® fans use an improved impeller with backward-curved blades and a toroidal inlet with a large inlet diameter.

The fundamental difference of UKROS is a flare-type upward discharge system with hinged protective pockets.

The impeller is mounted directly on the motor shaft. The fans are equipped with high-quality 3-phase asynchronous single-speed motors. Speed control by frequency converter is possible.

UKROS® fans have a well-thought-out housing design with a 4-sided and 6-sided motor cover shape, with a movable and very strong built-in gravity-type check valve that forms the flare discharge. Maximum protection against snow and rain is ensured (exceeds the protection of KROV and KROS fans).

Fans starting from size 071 are manufactured on a vibration-isolated base.

Mounting dimensions on the base plate are unified with KROV® roof fans.

Fans on the roof are easy to install using the STAM® mounting socket.

Additional fan options are available — see the catalog section «Additional equipment».

The fans can be operated in moderate (U), moderately cold (UHL) and tropical (T) climates, placement category 1 according to GOST 15150-69.

Operating conditions:

ambient temperature:

-from minus 45 to +40°C for moderate climate,

-from minus 60 to +40°C for moderate and cold climate,

-from minus 10 to +50°C for tropical climate;

average vibration velocity of external vibration sources at the fan installation points no more than 2 mm/s.

Specifications

  • Design:
  • - General industrial (H),
  • - Corrosion-resistant (K1),
  • - Explosion-proof (V, VS),
  • - Explosion-proof corrosion-resistant (VK1, VSK1)
  • Air outlet: flare outlet
  • Static pressure up to 2600 Pa
  • Flow rate: 1000 … 115000 m3/h
  • Climate version: U, UHL, T, placement category 1.