Automatic switch EKF va-99m 250/160a 3p 35ka

Price
On request
Brand
EKF
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

The VA-99M circuit breaker is made as a monoblock and consists of a base and a cover with a front panel that has a window for the control handle and a pusher for the «Test» button, used to check the breaker's trip mechanism.

The base is made of heat-resistant, non-flammable plastic and serves as the load-bearing structure for the connection clamps, fixed and moving contacts with the arc-extinguishing system, the control mechanism and the overcurrent protection unit. The cover encloses all moving elements of the control mechanism and the internal live parts.

For the full range of additional devices see pages 155-159.

ATTENTION! The breaker lever has three positions: «ON», «OFF» and «TRIPPED». To switch on after a trip, move the lever from the intermediate position to «OFF», and then to «ON».

The breaker's control mechanism is based on the toggle-lever principle and is equipped with a powerful return spring. When the control handle (4) is cocked, the insulating bar (5) is moved, on which the spring-loaded moving power contacts with flexible connections are mounted. The bar rotates in side guides, ensuring not only the closing of the moving and fixed power contacts, but also the necessary deflections to increase and equalize the pressure on the moving contacts. The action of the return spring is blocked by the toggle-lever elements, which at that moment lie on one straight line and rest with one knee on the protrusion of the «Reset» rotary element and the control mechanism. The control mechanism is reset by means of the flat bar (5), acted upon through the adjusting screws (6) by the pushers of the bimetallic plates of the thermal releases and the electromagnets of short-circuit protection. The arc-extinguishing system of the breakers is very effective in the VA-99M 125/125A and VA-99M 160/160A versions and consists of arc-extinguishing grids with steel nickel-plated arc-extinguishing inserts; in the VA-99M 250/250A and higher versions, additional arc diffusers in the form of thick steel perforated plates inserted into the cover are used. Nevertheless, when installing breakers in an enclosed volume of switchgear, the possibility of upward ejection of arc combustion products up to 30 mm in case of overcurrent protection operation must be taken into account.

Wires or busbars on the power source side are connected to the upper terminals of the breakers using bolts or clamps included in the delivery set. Wires or busbars to the load are connected to the lower terminals.

Switching with aluminium and copper conductors is possible.