The VA-99 circuit breaker is made as a monoblock and consists of a base and a cover with a front panel, which has a window for the control handle and a push button for the "Test" button — checking the breaker's tripping mechanism. The base is made of heat-resistant plastic that does not support combustion and serves as the load-bearing structure for the connection terminals, fixed and movable contacts with the arc-extinguishing system, the control mechanism and the overcurrent protection unit. The cover encloses all moving parts of the control mechanism and the internal current-carrying parts.
For the full range of additional devices see pp. 155-161.
ATTENTION! The breaker lever has three positions: "ON", "OFF" and "TRIPPED". To switch on after tripping, move the lever from the intermediate position to "OFF", and then to "ON".
The breaker's control mechanism is built on the toggle-lever principle and is equipped with a powerful return spring.
When the control handle is cocked, an insulating bar is set in motion, to which the spring-loaded movable power contacts with flexible connections are fixed. The bar pivots in side guides, ensuring not only the closing of the movable and fixed power contacts, but also the necessary deflection to increase and equalize the pressure on the movable contacts. The action of the return spring is blocked by the elements of the toggle lever, which at that moment lie on one straight line, resting with one knee on the protrusion of the "Reset" rotary element and the control mechanism. The control mechanism is "reset" by means of a flat bar, acted upon through adjusting screws by the pushers of the bimetallic plates of thermal releases and the electromagnets of short-circuit protection. The arc-extinguishing system of the breakers is very effective; however, when installing breakers in an enclosed volume of switchgear, it is necessary to take into account the possibility of upward ejection, up to 30 mm, of arc combustion products in the event of an overcurrent protection trip.
The supply-side wires or busbars are connected to the upper terminals of the breakers using the bolts or clamps included in the kit. Wires or busbars to the load are connected to the lower terminals. Connection of wires and busbars from the supply side from below, and wires and busbars to the load from above, is permitted. In this case all technical characteristics of VA-99ML remain unchanged.
Similar products
Automatic switch EKF va-99m 250/200a 3p 35ka
Automatic switch EKF va-99m 250/160a 3p 35ka
Automatic switch EKF va-99m 100/125a 3p 35ka
Automatic switch EKF va-99m 100/100a 3p 35ka
Automatic switch EKF va-99m 100/80a 3p 35ka
Automatic switch EKF va-99m 100/63a 3p 35ka
Automatic switch EKF va-99ml 100/80a 3p 18ka
Automatic switch EKF va-99ml 100/63a 3p 18ka
Automatic switch EKF va-99ml 63/32a 3p 15ka
Automatic switch EKF va-99ml 63/63a 3p 15ka
Automatic switch EKF va-99ml 63/20a 3p 15ka
Automatic switch EKF va-99ml 63/16a 3p 15ka
Company products
Automatic switch EKF va-99ml 63/80a 3p 15ka
Automatic switch EKF va-99m 63/63a 3p 25ka
Automatic switch EKF va-99m 63/50a 3p 25ka
Automatic switch EKF va-99m 63/40a 3p 25ka
Automatic switch EKF va-99m 63/32a 3p 25ka
Automatic switch EKF va-99ml 250/250a 3p 20ka
Automatic switch EKF va-99ml 250/225a 3p 20ka
Automatic switch EKF va-99ml 250/160a 3p 20ka
Automatic switch EKF va-99ml 250/125a 3p 20ka
Automatic switch EKF va-99ml 100/160a 3p 18ka
Automatic switch EKF va-99ml 100/125a 3p 18ka
Automatic switch EKF va-99ml 100/100a 3p 18ka