Automatic switch EKF va-99ml 100/100a 3p 18ka

Price
On request
Brand
EKF
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

The VA-99 circuit breaker is a monoblock design consisting of a base and a cover with a front panel that has a window for the control handle and a push button "Test" for checking the breaker's tripping mechanism. The base is made of heat-resistant plastic that does not support combustion and serves as the load-bearing structure for the connection terminals, fixed and moving contacts with the arc-quenching system, the control mechanism and the overcurrent protection unit. The cover encloses all moving elements of the control mechanism and the internal live parts.

For the full range of auxiliary devices see pages 155-161.

ATTENTION! The breaker lever has three positions: "ON", "OFF" and "TRIPPED". To switch on after tripping, the lever must be moved from the intermediate position to "OFF" and then to "ON".

The breaker control mechanism is based on the toggle lever principle and is fitted with a powerful return spring.

When the control mechanism handle is cocked, an insulating bar is set in motion, on which the spring-loaded moving power contacts with flexible connections are mounted. The bar rotates in the side guides, ensuring not only the closing of the moving and fixed power contacts but also the necessary travel to increase and equalize the pressure on the moving contacts. The action of the return spring is blocked by the elements of the toggle lever, which at that moment are on one straight line and rest with one knee on the projection of the "Reset" rotating element and of the control mechanism. The control mechanism is "reset" by means of a flat bar, on which the pushers of the bimetallic plates of the thermal releases and of the short-circuit protection electromagnets act through adjusting screws. The arc-quenching system

of the breakers is very effective; nevertheless, when installing breakers in a closed volume of switchgear, the possibility of combustion products of the arc being ejected upward to a distance of up to 30 mm in the event of overcurrent protection operation must be taken into account.

Wires or busbars on the supply side are connected to the upper terminals of the breakers with the bolts or clamps included in the delivery set. Wires or busbars to the load are connected to the lower terminals. Connection of wires and busbars from the supply side at the bottom and wires and busbars to the load at the top is permitted. In this case all technical characteristics of the VA-99ML remain unchanged.