The VA-99 circuit breaker is a monoblock design consisting of a base and a cover with a front panel that has a window for the operating handle and a plunger for the "Test" button, used to check the breaker's trip mechanism. The base is made of heat-resistant plastic that does not support combustion; it is the load-bearing structure for the connection terminals, fixed and moving contacts with the arc-quenching system, the operating mechanism and the overcurrent protection unit. The cover encloses all moving elements of the operating mechanism and the internal current-carrying parts.

For the full range of additional devices, see pages 155-161.

ATTENTION! The breaker lever has three positions: "ON", "OFF" and "TRIPPED". To switch on after a trip, move the lever from the intermediate position to "OFF", then to "ON".

The breaker's operating mechanism is built on the principle of a toggle lever and is fitted with a powerful return spring.

When the operating handle is cocked, an insulating bar carrying spring-loaded moving power contacts with flexible connections is set in motion. The bar pivots in side guides, providing not only the closing of the moving and fixed power contacts but also the necessary travel to increase and equalize the pressure on the moving contacts. The return spring action is blocked by the elements of the toggle lever, which at that moment are on one straight line, resting with one knee on the projection of the "Reset" rotary element and of the operating mechanism. The operating mechanism is reset by means of a flat bar, acted upon through adjusting screws by the plungers of the bimetallic strips of thermal releases and of the short-circuit protection electromagnets. The arc-quenching system of the breakers is very effective; however, when installing breakers in an enclosed volume of switchgear, the possibility of combustion products of the arc being ejected upward up to 30 mm in the event of an overcurrent trip must be taken into account.

Supply wires or busbars are connected to the upper terminals of the breakers using the bolts or clamps included in the kit. Wires or busbars to the load are connected to the lower terminals. Connecting wires and busbars from the power source at the bottom and wires and busbars to the load at the top is permitted. All technical characteristics of the VA-99ML remain unchanged in this case.