Automatic switch EKF va-99ml 63/50a 3p 15ka

Price
On request
Brand
EKF
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

The VA-99 circuit breaker is a monoblock design consisting of a base and a cover with a front panel, which has a window for the control handle and a plunger for the "Test" button, used to check the breaker's trip mechanism. The base is made of heat-resistant plastic that does not support combustion and serves as the load-bearing structure for the connection terminals, fixed and moving contacts with the arc-quenching system, the control mechanism, and the overcurrent protection unit. The cover encloses all moving elements of the control mechanism and the internal current-carrying parts.

For the full range of additional devices see pp. 155-161.

ATTENTION! The breaker lever has three positions: "ON", "OFF" and "TRIPPED". To switch on after a trip, move the lever from the intermediate position to "OFF", and then to "ON".

The breaker's control mechanism is based on the toggle-lever principle and is equipped with a powerful return spring.

When the control handle is cocked, an insulating bar is set in motion, on which the spring-loaded moving power contacts with flexible connections are mounted. The bar rotates in side guides, providing not only the closing of the moving and fixed power contacts but also the necessary travel to increase and equalise the pressure on the moving contacts. The action of the return spring is blocked by the elements of the toggle lever, which at that moment lie on one straight line, resting with one knee on the protrusion of the "Reset" rotary element and of the control mechanism. The control mechanism is "reset" by means of a flat bar, on which the pushers of the bimetallic plates of the thermal releases and of the short-circuit electromagnets act through adjusting screws. The system

of arc quenching of the breakers is very effective; however, when installing breakers in an enclosed volume of switchgear, one must take into account the possibility of arc combustion products being ejected upward to a distance of up to 30 mm when the overcurrent protection trips.

Wires or busbars on the supply side are connected to the upper terminals of the breakers using the bolts or clamps included in the delivery set. Wires or busbars to the load are connected to the lower terminals. It is permissible to connect wires and busbars from the supply side from below, and wires and busbars to the load from above. In this case, all technical characteristics of the VA-99ML remain unchanged.