Automatic switch EKF va-99m 800/800a 3p 50ka

Price
On request
Brand
EKF
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

The VA-99M circuit breaker is a monoblock design consisting of a base and a cover with a front panel that has a window for the control handle and a plunger for the “Test” button used to check the breaker’s trip mechanism.

The base is made of heat-resistant, non-flammable plastic and serves as the load-bearing structure for the connection terminals, fixed and moving contacts with the arc-quenching system, the operating mechanism and the overcurrent protection unit. The cover encloses all moving elements of the operating mechanism and the internal current-carrying parts.

For the full range of additional devices, see pages 155-159.

ATTENTION! The breaker lever has three positions: “ON”, “OFF” and “TRIPPED”. To switch on after a trip, move the lever from the intermediate position to “OFF” and then to “ON”.

The breaker operating mechanism is based on a toggle-lever principle and is equipped with a powerful return spring. When the operating mechanism handle (4) is charged, the insulating bar (5) is set in motion, to which the spring-loaded moving power contacts with flexible connections are fixed. The bar rotates in the side guides, ensuring not only the closing of the moving and fixed power contacts, but also the necessary travel to increase and equalize the pressure on the moving contacts. The action of the return spring is locked by the elements of the toggle lever, which at that moment lie on one straight line and rest with one knee on the projection of the “Reset” rotary element and of the operating mechanism. The operating mechanism is reset by the flat bar (5), on which the plungers of the bimetallic strips of the thermal releases and of the electromagnets for short-circuit protection act through the adjusting screws (6). The arc-quenching system of the breakers is highly effective in the VA-99M 125/125A and VA-99M 160/160A versions and consists of arc-quenching grids with steel nickel-plated arc-quenching inserts. In the VA-99M 25/250A version and above, additional arc splitters in the form of thick perforated steel plates inserted into the cover are used. However, when installing breakers in an enclosed volume of switchgear, one must take into account the possibility of arc combustion products being ejected upward to a distance of up to 30 mm in the event of an overcurrent protection trip.

Wires or busbars on the supply side are connected to the upper terminals of the breakers using the bolts or clamps included in the delivery set. Wires or busbars to the load are connected to the lower terminals.

Switching with aluminium and copper conductors is possible.