Automatic circuit breaker with electronic tripping device EKF VA-99 1600/1250A 3p 50ka

Price
On request
Brand
EKF
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

The VA-99 circuit breaker is a monoblock design consisting of a base and a cover with a front panel, which has a window for the control handle and a push button for the “Test” button, used to check the breaker's trip mechanism.

The base is made of heat-resistant, non-flammable plastic that serves as the load-bearing structure for the connection terminals, fixed and moving contacts with the arc-quenching system, the control mechanism, and the overcurrent protection unit. The cover encloses all moving elements of the control mechanism and the internal current-carrying parts.

ATTENTION! The breaker lever has three positions: “ON”, “OFF” and “TRIPPED”. To switch on after a trip, move the lever from the intermediate position to “OFF” and then to “ON”.

The breaker's control mechanism is based on a toggle-lever principle and is equipped with a powerful return spring. When the control handle is cocked, an insulating bar is set in motion, to which the spring-loaded moving power contacts with flexible connections are attached. The bar rotates in side guides, ensuring not only closing of the moving and fixed power contacts but also the necessary travel to increase and equalize the pressure on the moving contacts. The return spring action is locked by the elements of the toggle lever, which at that moment lie on one straight line, resting with one knee on the protrusion of the rotating “Reset” element and the control mechanism. The control mechanism is reset by a flat bar, which is acted upon through adjusting screws by the pushers of the bimetallic plates of thermal releases and the electromagnets of short-circuit protection.

The arc-quenching system of the breakers is very effective; in the VA-99 - 125/125A and VA-99 - 160/160A versions it consists of arc-chute grids with nickel-plated steel arc-quenching inserts; in the VA-99 - 25/250A version and higher, additional arc splitters are used in the form of thick perforated steel plates inserted into the cover. Nevertheless, when installing breakers in a closed volume of switchgear, one must take into account the possibility of upward ejection of arc combustion products up to 30 mm in the event of an overcurrent protection trip.

Wires or busbars on the power-supply side are connected to the upper terminals of the breakers using bolts or clamps included in the delivery set. Connection of supply busbars from below is permitted. Wires or busbars to the load are connected to the lower terminals.