Automatic switch with electric drive EKF va-99m 1250a 3p 35ka

- Price
- On request
- Brand
- EKF
- Country
- Uzbekistan
- Supplier
- ALFA POWER SOLUTIONS
- City
- Tashkent
The VA-99M circuit breaker is made as a monoblock and consists of a base and a cover with a front panel, which has a window for the control handle and a push button for the "Test" button — checking the breaker's tripping mechanism.
The base is made of heat-resistant plastic that does not support combustion and serves as the load-bearing structure for the connection terminals, fixed and movable contacts with the arc-extinguishing system, the control mechanism and the overcurrent protection unit. The cover encloses all moving parts of the control mechanism and the internal current-carrying parts.
For the full range of additional devices see pp. 155-159.
ATTENTION! The breaker lever has three positions: "ON", "OFF" and "TRIPPED". To switch on after tripping, move the lever from the intermediate position to "OFF", and then to "ON".
The breaker's control mechanism is built on the toggle-lever principle and is equipped with a powerful return spring. When the control handle (4) is cocked, the insulating bar (5) is set in motion, to which the spring-loaded movable power contacts with flexible connections are fixed. The bar pivots in side guides, ensuring not only the closing of the movable and fixed power contacts, but also the necessary deflection to increase and equalize the pressure on the movable contacts. The action of the return spring is blocked by the elements of the toggle lever, which at that moment lie on one straight line, resting with one knee on the protrusion of the "Reset" rotary element and the control mechanism. The control mechanism is "reset" by means of a flat bar (5), acted upon through adjusting screws (6) by the pushers of the bimetallic plates of thermal releases and the electromagnets of short-circuit protection. The arc-extinguishing system of the breakers is very effective in the VA-99M 125/125A and VA-99M 160/160A versions and consists of arc-extinguishing grids with steel nickel-plated arc-extinguishing inserts; in the VA-99M 250A and above versions, additional arc diffusers in the form of thick perforated steel plates inserted into the cover are used. Nevertheless, when installing breakers in an enclosed volume of switchgear, it is necessary to take into account the possibility of upward ejection, up to 30 mm, of arc combustion products in the event of an overcurrent protection trip.
The supply-side wires or busbars are connected to the upper terminals of the breakers using the bolts or clamps included in the kit. Wires or busbars to the load are connected to the lower terminals.
Connection with aluminum and copper conductors is possible.
Similar products
Manual rotary drive EKF to VA-99M 250
Additional contact EKF to VA-99M 1250
Additional contact EKF to VA-99M 400
Additional contact EKF to VA-99M 250
Emergency EKF to VA-99M 250
Emergency contact EKF to VA-99M 400
Block contact EKF bk-47
Automatic switch EKF va-99m 1250/1250a 3p 35ka
Automatic switch EKF va-99m 800/800a 3p 50ka
Automatic switch EKF va-99m 630/630a 3p 50ka
Automatic switch EKF va-99m 400/400a 3p 42ka
Automatic switch EKF va-99m 400/315a 3p 42ka
Company products
Minimum voltage release EKF to 230v ac va-99m 400
Minimum voltage release EKF to 230v ac va-99m 250
Automatic switch EKF va-99 800/1000a 3p 35ka
Automatic switch EKF va-99m 1600a 3p 35ka
Automatic circuit breaker with electronic tripping device EKF VA-99 1600/1250A 3p 50ka
Automatic circuit breaker with electronic tripping device EKF VA-99 1600/1600A 3p 50ka
Socket EKF RDE-47 240V
Socket EKF rd-47 240v
Independent release EKF rn-47
Call EKF zd-47
Minimum and maximum voltage release EKF RMM-47
Signal lamp EKF ls-47 (red)