Automatic switch EKF va-99m 1600a 3p 35ka

Price
On request
Brand
EKF
Country
Uzbekistan
Supplier
ALFA POWER SOLUTIONS
City
Tashkent

VA-99M circuit breaker is a monoblock design consisting of a base and a cover with a front panel that has a window for the control handle and a pusher for the "Test" button, used to check the breaker's trip mechanism.

The base is made of heat-resistant plastic that does not support combustion and serves as the load-bearing structure for the connection terminals, fixed and moving contacts with the arc-quenching system, the control mechanism, and the overcurrent protection unit. The cover encloses all moving parts of the control mechanism and the internal live parts.

For the full range of additional devices, see pp. 155-159.

ATTENTION! The breaker lever has three positions: "ON", "OFF" and "TRIPPED". To switch on after a trip, move the lever from the intermediate position to "OFF", and then to "ON".

The breaker's control mechanism is built on the toggle-lever principle and is equipped with a powerful return spring. When the control handle (4) of the mechanism is cocked, it moves the insulating bar (5), on which the spring-loaded moving power contacts with flexible connections are mounted. The bar rotates in the side guides, providing not only the closing of the moving and fixed power contacts, but also the necessary travel to increase and equalize the pressure on the moving contacts. The action of the return spring is locked by the elements of the toggle lever, which at that moment are on one straight line, resting with one knee on the protrusion of the "Reset" rotating element and of the control mechanism. The control mechanism is "reset" by means of the flat bar (5), which is acted upon through adjusting screws (6) by the pushers of the bimetallic plates of the thermal releases and of the short-circuit protection electromagnets. The arc-quenching system of the breakers is very effective in the VA-99M 125/125A and VA-99M 160/160A versions and consists of arc-quenching grids with nickel-plated steel arc-quenching inserts. In the VA-99M 25/250A and higher versions, additional arc splitters in the form of thick perforated steel plates inserted into the cover are used. Nevertheless, when installing breakers in a closed volume of switchgear, the possibility of combustion products of the arc being ejected upward to a distance of up to 30 mm in the event of an overcurrent trip must be taken into account.

Wires or busbars on the power source side are connected to the upper terminals of the breakers using the bolts or clamps included in the delivery set. Wires or busbars to the load are connected to the lower terminals.

Switching with aluminium and copper conductors is possible.