Excess pressure valve fire protection OXID



- Price
- On request
- Brand
- WINDCOM
- Country
- Uzbekistan
- Supplier
- WINDCOM
- City
- Tashkent
OKSID fire pressure relief valves are designed to compensate for the volume of removed combustion products in premises protected by exhaust smoke control ventilation, by compensating supply of outdoor air from vestibule airlocks or lift shafts in accordance with clause 8.8 of the code of practice SP 7.13.130.2013.
The valves are designed for installation in the walls of vestibule airlocks or lift shafts directly adjacent to the protected premises.
The valves comply with seismic resistance requirements for seismic impacts of intensity 9 on the MSK-64 scale.
Version:
- General industrial (N);
- Corrosion-resistant (K);
- Frost-resistant (MS);
- Frost-resistant and corrosion-resistant (MSK).
Valve type:
• Wall type (1*f);
• Duct type (2*f).
The valves are rectangular-section housings made of galvanized steel (N and MS versions) or stainless steel (K and MSK versions), with one or more pivoting blades installed inside. The blade is made of a fire-resistant material with low thermal conductivity, moisture resistance, frost resistance and environmental safety. A spring mechanism for setting the opening pressure of the valve is installed inside the housing; adjustment is carried out during commissioning of the smoke control ventilation.
In the frost-resistant versions (MS/MSK) the valves are equipped with a flexible self-regulating heating cable (heater) to prevent the blade from freezing to the housing.
The valve is designed for vertical installation, with the blade's rotation axis horizontal and the spring mechanism located below the blade's rotation axis.
Specifications
- Fire resistance rating: EI 90
- Specific smoke-gas permeability resistance: >=11200 m³/kg
- Maximum air flow speed: 15 m/s
- Valve opening start pressure adjustment range: 20 ... 150 Pa
- Maximum static pressure on the valve: 2000 Pa
- Heating element power:
- nominal power consumption of the heated heating element: 0.03 kW/m
- maximum starting power of the heating element at -10°C: 0.2 kW/m.
- Nominal heating element voltage: 220V (50 Hz).
- Thermal resistance coefficient through the valve section: 0.61 m²K/W
Similar products
Insulated vestibule valve GERMIKx2S
Insulated vestibule valve GERMIKH2P
Excess pressure relief valve KID
Universal fire damper KPU-DD
Universal fire damper KPU-DD
Universal fire damper KPU-2N
Air valves GERMIK-P, GERMIK-R and GERMIK-S
Flashlight easily discarded VZRYVOZOR-200
Flashlight easily discarded VZRYVOZOR-100
Anti-aircraft blind lantern NEBOZOR-100
Anti-aircraft blind lantern NEBOZOR-200
Hatch HODOZOR-100
Company products
Universal fire damper KPU-2N
Universal fire damper KPU-1N
Universal fire damper KPU-1N
Fire-prevention check valve PROK
Fire-prevention check valve PROK
Fire damper GERMIK-DU
Smoke valve KED
Balancing valve CLUB
Hermetic ventilation valve GEK
Air check valve NERPA-KO
High Density Air Valve NERPA
High Density Air Valve NERPA