GERMIK®x2S is designed for passive thermal insulation of the served volume under conditions of relatively high pressure differentials. It is an insulated vestibule damper with two perpendicularly arranged blade groups, designed to operate at low temperatures (down to minus 60°C) thanks to perimeter heating and actuator heating. Such a damper also has a higher leakage class in the closed position than the GERMIK® damper with a single blade group.
Versions:
-General industrial with aluminum blade (H);
-General industrial with zinc-coated steel blade (Ts);
-Corrosion-resistant (K).
The dampers consist of two perpendicularly oriented blade sections of GERMIK®-S dampers. The damper sections are separated by a special thermally insulating spacer with a bolted connection. Each of the two damper sections has a box-type body made of galvanized steel (versions • H • Ts) or stainless steel (version • K). The damper blades are made of aluminum profile (versions • H • K) or galvanized steel profile (version • Ts). Due to the double body design, the damper length increases to 340 mm.
The separating thermal insulation spacer prevents cold transfer through the body material. The outer perimeter of each damper section is covered with a protective layer of thermal insulation material and has heating, which excludes convective transfer of cold into the room served by the damper. All actuators are also equipped with heating. Each blade section is driven by its own actuator - there is no direct mechanical link between the sections. The kinematics of each blade section are levers and rods.
As standard, the dampers can be equipped with VEZA actuators. On special order, dampers with BELIMO actuators or actuators from other manufacturers can be produced.
Specifications
- Purpose: shut-off
- Duct valve
- Working pressure up to 1800 Pa
- Working medium velocity up to 20 m/s
- Actuator: electric drive
- 3rd leakage class
- Blade opening: parallel
- Arbitrary spatial orientation
- Climatic design per GOST 15150-69: UHL2
- Heat transfer resistance across the valve section:
- - version H, K: 1,69 m2*K/W
- - version Ts: 2,12 m2*K/W.
- Perimeter heating element (TEN) power:
- - rated power consumption of the heated TEN: 0,03 kW/m
- - maximum starting power2 of the TEN at minus 10 °C: 0,2 kW/m.
Similar products
Mounting frame MRP
Mounting frame MRP
Mounting frame MRZ
Noise suppression plates PLAST
PLAG noise reduction plates
Check valve UKOL
Universal fire damper KPU-1N
Universal fire damper KPU-1N
Fire-prevention check valve PROK
Fire-prevention check valve PROK
Fire damper GERMIK-DU
Excess pressure valve fire protection OXID
Company products
Check valve UKOL
Check valve TULIP
Check valve NERPA-KO
Check valve KOL
Linear expansion compensator COM 560
High-density valves KEDR and KEDR-S
Insulated vestibule valve GERMIKH2P
Excess pressure relief valve KID
Universal fire damper KPU-DD
Universal fire damper KPU-DD
Universal fire damper KPU-2N
Universal fire damper KPU-2N